DIATERMO MB 400D - mono-bipolar

DIATERMO MB300 and MB400 are high frequency electrosurgical equipments suitable to deliver current for monopolar cut and coagulated cut (with different levels of coagulation), bipolar cut and coagulation. TWIN OPERATIVE ACTIVITY - Two output channels for monopolar cutting - Two independent setting and output channels for the most frequent monopolar coagulation CONTROLLED CUTTING PROCEDURES - Enhanced cutting current for eschar free incision - Cutting current with selectable coagulating property for bleeding controlled dissection - Low capacitance coupling by slow BLEND current for endoscopic procedures TWIN CONTROLLED COAGULATION PROCEDURES - SPEEDY coagulation and DEEP coagulation available to two operators - SPRAY coagulation by hand switch or foot switch controls EXTENSIVE BIPOLAR FEATURES - Bipolar cutting current with selectable bleeding control - Slow BLEND cutting current - Automatic Start/Stop coagulation functions SURGEON AND PATIENT TOTAL SAFETY - Acceptability of contact impedance between patient body and return electrode continuously monitored by Skin Plate Electronic Control (SPEC) - H.F. Leakage currents continuously monitored - Mains fluctuation automatically compensated before delivery of HF power PERSONALIZED PROCEDURES - Independent choice of coagulation currents and power levels by each of two operators - Up to 10 procedures can be configured and re-called EXTENSION DRIVER AND INTERLOCK SIGNALS - Driven output connection to external Argon Plasma unit and Smoke Evacuator unit AUTOMATIC SELF DIAGNOSIS - Automatic diagnostic control of the complete functionality of electronic unit and connected accessories with coded report of failures SUITABLE IN: - OUTPATIENT SURGERY - GENERAL SURGERY - PAEDIATRIC SURGERY - PLASTIC SURGERY - THORAX SURGERY - VASCULAR SURGERY - DERMATOLOGY - ENDOSCOPY - GASTROENTEROLOGY - GYNAECOLOGY - NEUROSURGERY - ORTHOPEDICS - OTORHINOLARINGOLOGY - PNEUMOLOGY - UROLOGY - VETERINARY

Add to your Wish List
Item #: 66834

Unità di vendita: 1 pc.
Quantitativi minimi: 1
NSIS:
CND:

 
€ 4.900,00 € 5.390,00
(€ 6.575,80 IVA Inclusa 22%)


• Maximum out power monopolar pure CUT: 400 W - 300 Ω
• Maximum out power monopolar cut-coag CUT80%: 350 W - 300 Ω
• Maximum out power monopolar cut-coag CUT60%: 250 W - 300 Ω
• Maximum out power monopolar cut-coag CUT40%: 200 W - 300 Ω
• Maximum out power monopolar cut ENHANCED: 250 W - 500 Ω
• Maximum out power monopolar cut-coag BLEND: 250 W - 300 Ω
• Maximum out power monopolar coag SPEEDY: 120 W - 500 Ω
• Maximum out power monopolar coag DEEP: 120 W - 200 Ω
• Maximum out power monopolar coag SPRAY: 100 W - 2000 Ω
• Maximum out power monopolar coag SPRAY ARGON: 100 W - 2000 Ω
• Maximum out power bipolar CUT 95 W - 150 Ω
• Maximum out power bipolar cut-coag CUT80%: 95 W - 150 Ω
• Maximum out power bipolar cut-coag CUT60%: 95 W - 150 Ω
• Maximum out power bipolar cut-coag CUT40%: 60 W - 150 Ω
• Maximum out power bipolar cut-coag BLEND: 90 W - 150 Ω
• Maximum out power bipolar cut-coag BLEND: 70 W - 100 Ω
• Working frequency monopolar/bipolar: 425 kHz / 525 kHz
• Patient circuit: F
• Selectable input voltage: 115-230 Vac
• Mains frequency: 50-60 Hz
• Electrical input voltage: 1000 VA
• Size WxHxD: 470 x 150 x 400 mm
• Weight: 17.5 Kgs
• Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
• Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF, MDD 93/42/EC Class: II b